Advertisement

Picture Gallery
Search Our Site

Search:



Apparatus Gallery
Visitor Poll

What trucks responds on MVAs



Contact Information

Waterloo Vol Fire Co Inc
PO Box 513
Waterloo, NY  13165

Non-Emergency:
315-539-2161

Emergency:
911

Contact Us
Map

Links

Seneca County Training Dates

Up coming training for Seneca County


Firefighting Powder Aerosol Generator

This thing is great - Check out the videos


Firehouse training Videos




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 | 2 |

Call Fighter
Call firefighters respond as needed on a part time basis to all types of emergencies. Call firefighters train with their local engine companies in their districts. Call firefighters are utilized in three different ways. First Responder call firefighter units are those units that are staffed entirely by paid call firefighters. These firefighters respond to all emergency incidents within their jurisdictional areas and are supported by full-time companies from adjoining jurisdictions. "Supplemental" call firefighter units are those units that staff a second engine company from a station that is also staffed by a full-time company. These units respond to all multi-unit responses in their district and cover the station when the career companies are committed. "Augmentation" call firefighters are assigned to an existing career company and respond directly to the scene to augment that company's staffing.


Cellar fire
Cellar fires are difficult to attack directly because firefighters have to pass through the hot gasses and smoke accumulated on the cellar's ceiling to gain access to the cellar space. Cellars typically do not have good emergency egress points, adding to the danger.


Cellar pipe
Cellar Nozzle. A distributing type nozzle that is inserted through an opening in the floor and into the space below, typically a basement or cellar. The nozzle directs a broken stream horizontally, either extinguishing or controlling the fire enough to allow a direct attack to be safely made. Can also be used on top of other containers.


CFA 3-Thread
A type of coupling used by the CFA, it is used mainly on the australian 64mm hose, it provides a very secure coupling, obviously the threading of the coupling is repeated 3 times, it is non-hemaphoradite.


Charged line
Fire hose under pressure from the pump at the engine.


Check valve
See backflow preventer


Chimney fire
Fast and intense fire in a chimney flue in which accumulated creosote and other combustion byproducts ignite.


Class A, B, C, D, K
Classes of fire extinguisher and corresponding type of fire they extinguish.


Closed area
An area in which specified activities or entry are temporarily restricted to reduce risk of human-caused fires.


Closed-circuit SCBA
See SCBA.


Closet hook
Pike pole under 5 ft long


Closet ladder
See Attic ladder.


Closure
Legal restriction, but not necessarily elimination, of specified activities such as smoking, camping, or entry that might cause fires in a given area.


CO2 extinguisher
Fire extinguisher that releases carbon dioxide gas to smother and cool a fire, such as a flammable liquid.


Cockloft
Structural space above ceiling and below rafters, often connecting adjacent occupancies and permitting fire to spread laterally, often unseen.


Cold trailing
A method of controlling a partly dead fire edge by carefully inspecting and feeling with the hand for heat to detect any fire, digging out every live spot, and trenching any live edge.


Collapse zone
The area around a structure that would contain debris if the building were to collapse.


Combination nozzle
A low pressure Fog Nozzle (usually 120 to 150 lbf/inē or 820 to 1030 [[kilopascal|kPa)) that can be adjusted to produce a near straight stream. Also commonly referred to as a Taskforce Tip (TFT).


Company
Two or more firefighters organized as a team, led by a fire officer, and equipped to perform certain operational functions. Compare with platoon and unit.


Compartment Fire
An Isolated" fire or a fire which is "boxed in" or "closed off" from the rest of the structure. An example of this is a fire in a room where all the windows and doors are closed preventing the fire from spreading to other rooms.





Recent Calls

Tue. Aug 31st 2010
Outdoor fire

Waterloo fire was dispatched at 18:38 for the reported outdoor fire on chestnut st in the village. 1663 responded and turned ...

Read more »


Mon. Aug 30th 2010
Assist with Junius fire dept

Waterloo fire department was dispatched at 14:00 to assist junius fire depatment on a pi mva. A special request from jun...

Read more »


Mon. Aug 30th 2010
fire alarm

Waterloo fire dispatched at 17:55 for a fire alarm at the middle school. 1661 arrived on scene 1759 with nothing showing. uni...

Read more »

Upcoming Events

Every 1st Mon. 7:00pm
Monthly meeting


Last Thu. of the month 7:00pm
Line Officers Meeting


Every Thu. 7:00pm
Officer Night

2010 Call Volume
January  28
February  17
March  29
April  28
May  31
June  27
July  28
August  30
September  
October  
November  
December  
Total 218

View Call Volume History

Newsletter Subscription

Stay up to date!
Subscribe to our Newsletter.


Enter Your Email Address:




YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Waterloo Vol Fire Co Inc. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Waterloo Vol Fire Co Inc.

This site has been
viewed 326,159 times.
Advertisement